Concentrations settings

Selection settings

Table 57 Selection settings for module Concentrations.
Name Description
Concentrations tier
Specifies the concentration data should be treated according to a pre-defined tier or custom.
Filter samples exceeding the concentration limits
If checked, samples with at least one substance concentration higher than some factor (concentration limit filter exceedance factor) times the MRL are filtered out.
Concentration limit filter exceedance factor
The multiplication factor for the concentration limit exceedance filter.
Use substance conversion rules
If checked, concentrations are modelled in terms of active substances (using substance conversion).
Substance conversion method
Allocation method for assigning active substance concentrations from measured substance concentrations based on substance translations.
Retain all allocated substances after active substance allocation
If checked, all allocated substances kept after substance conversion. Otherwise, the concentration data is restricted to the active substances of the assessment group.
Account for substance authorisations in substance conversions
Account for substance authorisations when allocating measured substances to active substance using substance conversions.
Fix duplicate substance allocation inconsistencies
Resolve inconsistencies when active substance allocation leads to multiple concentration value estimates for the same active substance. This method uses the mean of the positives or zero concentrations when available, or else the lowest of the non-detect values.
Use extrapolation rules
Use extrapolation rules to extrapolate food samples for foods with a limited amount of samples (data poor foods) from other foods (data rich foods).
Threshold for extrapolation
Threshold for extrapolation.
Restrict extrapolations to equal MRLs
Restrict extrapolations to equal MRLs.
Restrict extrapolations to authorised uses
Only extrapolate if substance use is authorised.
Impute water concentrations
Impute constant concentration values on the selected (water) commodity.
Water commodity
The commodity for which constant concentration values should be added.
Water concentration value (µg/kg)
Constant concentration value that should be used for water (in µg/kg).
Restrict water imputation to the five most toxic substances
Restrict water imputation to the five most toxic substances.
Restrict water imputation to authorised uses
Restrict water imputation to authorised uses.
Include focal commodity concentrations
Specifies whether there is monitoring data that should replace part of the consumption data for the specified focal commodities.
Focal commodity foods
The foods for which background concentration data are to be replaced by focal commodity concentrations.
Focal commodity substances
The substances for which background concentration data are to be replaced by focal commodity concentrations.
Focal commodity concentrations replacement method
Replacement method to be used for replacing base concentration data with concentration data of the focal commodity/commodities concentrations.
Focal commodity substance occurrence percentage
Anticipated occurrence percentage / agricultural use percentage of the focal commodity.
Adjustment factor for the focal food/substance concentration
Optional adjustment factor for the focal food/substance concentration. E.g., the expected ratio of mean monitoring concentration and mean field trial concentration.
Use deterministic substance conversions for focal commodity
Convert measured substance concentrations of focal commodity to active substance concentrations using deterministic substance conversion factors.
Filter samples by specific property values (subset selection)
Specifies whether a subset selection on specific sample properties should be made (e.g., by country or by year).
Sample locations
The locations for which samples are filtered.
Sample years
The years for which samples are filtered.
Modelled-foods subset: restrict to specific modelled-foods
If checked, then the assessment is restricted to the specified modelled foods.

Uncertainty settings

Table 58 Uncertainty settings for module Concentrations.
Name Description
Resample concentrations
Specifies whether concentrations are resampled by empirical bootstrap or using a parametric uncertainty model.