Kinetic conversion factors settings

Calculation settings

Table 419 Calculation settings for module Kinetic conversion factors.
Name Type Description
Exposure type
ExposureType The type of exposure considered in the assessment; acute (short term) or chronic (long-term).
Multiple substances analysis

Boolean

Specifies whether the assessment involves multiple substances.
Exposure routes

ExposureRoutes

Exposure routes included in assessment.
Restrict active substances to substances with available hazard characterisations

Boolean

Restrict assessment group membership based on presence/absence of hazard characterisations.
Use kinetic conversion factors subgroup

Boolean

Kinetic conversion factors are dependent on subgroups (e.g. based on age or gender, see dataformats KineticConversionfactorsSGs).
Target biological matrix
BiologicalMatrix The internal target/matrices for which kinetic conversion factors are to be computed.
PBK model simulations

Numeric

Number of PBK model simulations used to derive kinetic conversion factors from PBK model simulations.
Exposure range minimum

Numeric

Minimum of the external exposure range for PBK model simulations used to derive kinetic conversion factors from PBK model simulations.
Exposure range maximum

Numeric

Maximum of the external exposure range for PBK model simulations used to derive kinetic conversion factors from PBK model simulations.
Compute between internal target conversion factors

Boolean

Compute kinetic conversion factors to extrapolate exposures/concentrations between internal targets/matrices.
Number of simulated days

Numeric

The total duration (in days) of the PBK model simulations.
Exposure events and dose generation method
ExposureEventsGenerationMethod Generates doses and events for PBK model
Number of initial days skipped

Numeric

The initial period (or burn-in period, specified in days) that needs to be skipped when calculating the steady-state or peak internal exposures from the simulated time series.
Number of initial years skipped

Numeric

The initial period (or burn-in period, specified in years) that needs to be skipped when calculating the steady-state or peak internal exposures from the simulated time series.
Use PBK model parameter variability

Boolean

When specified, use parameter variability.
PBK simulation method
PbkSimulationMethod Specifies in which mode to run the PBK model
Expected life time in years

Numeric

The total expected lifetime (in years) of the PBK model.
Use bodyweight adjusted exposures

Boolean

Use bodyweight adjusted exposures in PBK model simulations.
PBK output resolution time unit
PbkModelOutputResolutionTimeUnit Time unit in which the output resolution of PBK model simulations is specified.
PBK output resolution step size

Numeric

PBK model simulation output step size/length, specifying the evaluation resolution in terms of the step length (period) between two evaluations. For example, a step length of 12 with a resolution time unit of hours is interpreted as every 12 hours.
Seed for pseudo-random number generator

Numeric

A value of 0 will use a pseudo-random seed in each run, a value > 0 will provide the same results in a repeated run.

Uncertainty settings

Table 420 Uncertainty settings for module Kinetic conversion factors.
Name Type Description
Resample kinetic conversion factors

Boolean

Specifies whether kinetic conversion factors are resampled.